!RANDBEDINGUNGSWERTE FESTLEGEN !Einheit m,s,Kg,N,C,W, *DIM,Densi,ARRAY,8 *DIM,TLeit,ARRAY,8 *DIM,SWaer,ARRAY,8 !*DIM,Enthalpy,ARRAY,8 *DIM,Tempe,ARRAY,8 Tempe(1) = 25,100,200,300,400,500,600,750 !Temperatur [C] Densi(1) = 2811.2,2796.5,2775.6,2753.47,2729.8,2704.9,2630,2477.9 !Dichte [Kg/m^3] TLeit(1) = 121.1,129.4,138.6,146.6,154.1,160.5,131.6,83.86 !Thermische Leitfähigkeit [W/m C] SWaer(1) = 860.4,900.7,943.7,983.6,1024.2,1136.6,5697.9,1123.4 !Spezifische Waermekapazitaet [J/Kg C] /PREP7 !KNOTEN !Wuerfel1 N,1,0,0,0 N,2,2,0,0 N,3,2,2,0 N,4,0,2,0 N,5,0,0,2 N,6,2,0,2 N,7,2,2,2 N,8,0,2,2 N,9,1,0,0 N,10,2,1,0 N,11,1,2,0 N,12,0,1,0 N,13,1,0,2 N,14,2,1,2 N,15,1,2,2 N,16,0,1,2 N,17,0,0,1 N,18,2,0,1 N,19,2,2,1 N,20,0,2,1 NSEL,S,NODES,,1,20 CM,WuerfelN1,NODE !Wuerfel2 N,21,2,0,0 N,22,4,0,0 N,23,4,2,0 N,24,2,2,0 N,25,2,0,2 N,26,4,0,2 N,27,4,2,2 N,28,2,2,2 N,29,3,0,0 N,30,4,1,0 N,31,3,2,0 N,32,2,1,0 N,33,3,0,2 N,34,4,1,2 N,35,3,2,2 N,36,2,1,2 N,37,2,0,1 N,38,4,0,1 N,39,4,2,1 N,40,2,2,1 NSEL,S,NODES,,21,40 CM,WuerfelN2,NODE !SOLID *GET,Enum,ELEM,0,COUNT *GET,ETyp,ELEM,0,TYPM Enummax = Enum +1 Etypmax = ETyp +1 !Wuerfel1 ET,Etypmax,90 TYPE,Etypmax MAT,Etypmax REAL,Etypmax SECNUM,Etypmax E,1,2,3,4,5,6,7,8 EMORE,9,10,11,12,13,14,15,16 EMORE,17,18,19,20 ESEL,S,TYPE,,Etypmax CM,WUERFEL1,ELEM !Named selection csys,0 toffst,273.15 ! Temperature offset from absolute zero MPTEMP,,,,,,,, MPTEMP,1,Tempe(1) MPTEMP,2,Tempe(2) MPTEMP,3,Tempe(3) MPTEMP,4,Tempe(4) MPTEMP,5,Tempe(5) MPTEMP,6,Tempe(6) MPTEMP,7,Tempe(7) MPTEMP,8,Tempe(8) MPDATA,DENS,Etypmax, ,Densi(1),Densi(2),Densi(3),Densi(4),Densi(5),Densi(6), MPDATA,DENS,Etypmax, ,Densi(7),Densi(8), ! kg m^-3 MPTEMP,,,,,,,, MPTEMP,,,,,,,, MPTEMP,1,Tempe(1) MPTEMP,2,Tempe(2) MPTEMP,3,Tempe(3) MPTEMP,4,Tempe(4) MPTEMP,5,Tempe(5) MPTEMP,6,Tempe(6) MPTEMP,7,Tempe(7) MPTEMP,8,Tempe(8) MPDATA,KXX,Etypmax, ,TLeit(1),TLeit(2),TLeit(3),TLeit(4),TLeit(5),TLeit(6), MPDATA,KXX,Etypmax, ,TLeit(7),TLeit(8), ! W m^-1 C^-1 MPTEMP,,,,,,,, MPTEMP,,,,,,,, MPTEMP,1,Tempe(1) MPTEMP,2,Tempe(2) MPTEMP,3,Tempe(3) MPTEMP,4,Tempe(4) MPTEMP,5,Tempe(5) MPTEMP,6,Tempe(6) MPTEMP,7,Tempe(7) MPTEMP,8,Tempe(8) MPDATA,C,Etypmax, ,SWaer(1),SWaer(2),SWaer(3),SWaer(4),SWaer(5),SWaer(6), MPDATA,C,Etypmax, ,SWaer(7),SWaer(8), ! J kg^-1 C^-1 MPTEMP,,,,,,,, Etypmax = Etypmax +1 !Wuerfel2 ET,Etypmax,90 TYPE,Etypmax MAT,Etypmax REAL,Etypmax SECNUM,Etypmax E,21,22,23,24,25,26,27,28 EMORE,29,30,31,32,33,34,35,36 EMORE,37,38,39,40 ESEL,S,TYPE,,Etypmax CM,WUERFEL2,ELEM !Named selection MPTEMP,,,,,,,, MPTEMP,1,Tempe(1) MPTEMP,2,Tempe(2) MPTEMP,3,Tempe(3) MPTEMP,4,Tempe(4) MPTEMP,5,Tempe(5) MPTEMP,6,Tempe(6) MPTEMP,7,Tempe(7) MPTEMP,8,Tempe(8) MPDATA,DENS,Etypmax, ,Densi(1),Densi(2),Densi(3),Densi(4),Densi(5),Densi(6), MPDATA,DENS,Etypmax, ,Densi(7),Densi(8), ! kg m^-3 MPTEMP,,,,,,,, MPTEMP,,,,,,,, MPTEMP,1,Tempe(1) MPTEMP,2,Tempe(2) MPTEMP,3,Tempe(3) MPTEMP,4,Tempe(4) MPTEMP,5,Tempe(5) MPTEMP,6,Tempe(6) MPTEMP,7,Tempe(7) MPTEMP,8,Tempe(8) MPDATA,KXX,Etypmax, ,TLeit(1),TLeit(2),TLeit(3),TLeit(4),TLeit(5),TLeit(6), MPDATA,KXX,Etypmax, ,TLeit(7),TLeit(8), ! W m^-1 C^-1 MPTEMP,,,,,,,, MPTEMP,,,,,,,, MPTEMP,1,Tempe(1) MPTEMP,2,Tempe(2) MPTEMP,3,Tempe(3) MPTEMP,4,Tempe(4) MPTEMP,5,Tempe(5) MPTEMP,6,Tempe(6) MPTEMP,7,Tempe(7) MPTEMP,8,Tempe(8) MPDATA,C,Etypmax, ,SWaer(1),SWaer(2),SWaer(3),SWaer(4),SWaer(5),SWaer(6), MPDATA,C,Etypmax, ,SWaer(7),SWaer(8), ! J kg^-1 C^-1 MPTEMP,,,,,,,, Etypmax = Etypmax +1 !KOMPONENT CMSEL,S,WUERFEL2 !NEW NSLE,ALL !NEW *GET,XMax,NODE,0,MXLOC,X !NEW NSEL,R,LOC,X,XMax,XMax !NEW SF,ALL,CONV,40000,35 !CONTACT PAIR CMSEL,S,WUERFEL1 NSLE,ALL NSEL,R,LOC,X,2,2 CM,SSXY1,NODE CMSEL,S,WUERFEL2 NSLE,ALL NSEL,R,LOC,X,2,2 CM,SSXY2,NODE !!HIER SOLL DER CODE FÜR DAS ERSTELLEN DER KONTAKTE STEHEN !SOLU /SOLU ANTYPE,4 TRNOPT,FULL TUNIF,700 !Anfangstemperatur festlegen TIME,20 NSUBST,100,1000,10 OUTRES,ERASE OUTRES,ALL,1 ALLSEL EPLOT